how to use osha standard for coupling guard

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • Coupling Guards - OSHA Requirements | Coupling

    2014-10-9 · Labels: 29 CFR 1910, bellhousing, coupling cover, coupling guard, coupling guard requirements, CSA Standard Z432, flower pot, OSA coupling guard, OSHA coupling requirements, OSHA requirements, pump motor mount

    Get Price
  • Requirement to guard shaft couplings. | Occupational ...

    2021-7-25 · Standard Interpretations. Requirement to guard shaft couplings. Standard Number: 1910.219 (i) (2) OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations.

    Get Price
  • OSHA Machine Guarding Standards - Machine Guard

    OSHA does not approve guards separate from specific guard applications. Our machine guarding products, if installed correctly, meet OSHA machine guarding standards for most applications. The only exception is underground mining, covered by a different standard. We can help ensure that the guard for your application, if properly installed, will be ...

    Get Price
  • Requirements for machine and machinery guarding in

    1997-12-8 · Additionally, under paragraph 1910.219 (m) (1), the stationary casing must be securely fastened to the floor or frame of the machine (pump coupling). In the brochure enclosed with your letter, you stated that your shield 'is easy to install or to remove.

    Get Price
  • How To Use a Guard Opening Scale - Machine Safety

    1979-1-26 · Appropriate guarding of lathe chucks. Standard Number: 1910.212 (a) (1) OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of ...

    Get Price
  • Appropriate guarding of lathe chucks. | Occupational ...

    The machine guards must be attached to the machine or placed in a secured area to be used by any worker or operator who will be in contact with the machine. The machine guard itself must also be protected from damaging factors. OSHA 1910.212(a) (3) (ii) The machine guard that will be used must be manufactured based on approved standards.

    Get Price
  • OSHA Machine Guards Regulations for Pumping

    2021-7-27 · 1910.219 (c) (5) (i) The basement, tower, or room occupied by transmission equipment is locked against unauthorized entrance. 1910.219 (c) (5) (ii) The vertical clearance in passageways between the floor and power transmission beams, ceiling, or any other objects, is not less than five feet six inches (5 ft. 6 in.).

    Get Price
  • Coupling Guard - PumpBiz

    They have an OSHA-required enhanced end-cap design and can shield pillow-block bearings from dirt and debris. They meet OSHA standard 29 CFR 1910.219 for rotating machinery. Each guard comes unassembled, allowing you to custom fit your application. Type 304 stainless steel hardware included. 4' x …

    Get Price
  • OSHA Standards on Machine Guarding

    2017-11-30 · OSHA Standards on Machine Guarding The OSHA standards on general guarding of machinery and mechanical power transmission apparatus (29 CFR 1910.212 and 1910.219) are very broad and generally minimum guarding standards. One standard was predicated on the 1970’s version of the ANSI/ASME B15.1 standard, which itself had

    Get Price
  • Coupling, Coupling Guard, Isolated & Base Frame

    2020-3-23 · Coupling Guard Design Features Safety Comes First Orange Peel guards comply with OSHA, ASME and ANSI standards, and most other guards don't. Look for a Safety Orange guard, gaps no greater than 0.250' (6 mm) and ANSI Z535.4 compliant warning labels.

    Get Price
  • Coupling Guard for Pumps Increases Worker Safety

    2017-9-14 · New Coupling Guard Increases Worker Safety. Coupling guards are an essential, but often overlooked, piece of equipment created to keep the user from harm. A typical coupling guard is mounted to the frame of a pump, which can cause it to be ill-fitting. This is problematic for sanitary processing facilities because the result is an unsafe, non ...

    Get Price
  • Coupling Guards - dalcopumps.com

    Coupling guard design is acceptable. 3. Advise coupling vendor or any environmental considerations that may affect dry flexible element life (environmental gases, temperatures, excessive dust, etc.). B.P. 4.3: Always match-mark hydraulic fit coupling to shaft in order to observe if the coupling slipped at all.

    Get Price
  • OSHA Guard Safety Scale | Danray Products

    2006-3-21 · The standard also requires use of PPE to guard workers against electrical hazards, but doesn’t specify which equipment to use [Sec. 1910.335(a)(1)(i)]. NFPA 70E is a national consensus safety standard published by the NFPA to help OSHA prepare electrical safety standards. Unlike the OSHA PPE Standard, NFPA 70E does get into the specifics

    Get Price
  • Coupling Guards - OSHA Requirements | Coupling

    2014-10-9 · Labels: 29 CFR 1910, bellhousing, coupling cover, coupling guard, coupling guard requirements, CSA Standard Z432, flower pot, OSA coupling guard, OSHA coupling requirements, OSHA requirements, pump motor mount

    Get Price
  • Requirement to guard shaft couplings. | Occupational ...

    2021-7-25 · According to your letter description and the enclosed pictures which show a sheet metal sleeve bolted to the motor/pump base totally covering the coupling we believe that you are in total compliance with OSHA 1910.219(i)(2) on page 23730 of the …

    Get Price
  • OSHA Machine Guarding Standards - Machine Guard

    Safety Standard for Guarding of Machinery and Mechanical Power Transmission Apparatus. The OSHA standards on general guarding of machinery and mechanical power transmission apparatus (29 CFR 1910.212 and 1910.219) are very broad and general minimum guarding standards, one of which was predicated on the 1970’s version of the ANSI/ASME B15.1 standard, which itself had undergone …

    Get Price
  • 1910.219 - Mechanical power-transmission apparatus ...

    2021-7-27 · 1910.219 (c) (5) (i) The basement, tower, or room occupied by transmission equipment is locked against unauthorized entrance. 1910.219 (c) (5) (ii) The vertical clearance in passageways between the floor and power transmission beams, ceiling, or any other objects, is not less than five feet six inches (5 ft. 6 in.).

    Get Price
  • OSHA Machine Guards Regulations for Pumping

    OSHA 1910.212(a) (3) (ii) The machine guard that will be used must be manufactured based on approved standards. In the absence of standards, it must be manufactured in such a way that it protects the operators’ body parts from any risk in the danger zone. OSHA 1910.212(a) (3) (iii)

    Get Price
  • Safeguarding Equipment and Protecting Employees from ...

    2020-9-24 · OSHA standard may be. However, when a consen-sus standard addresses safety considerations,OSHA may determine that the safety practices described by that consensus standard are less protective than the requirement(s) set forth by the pertinent OSHA regulations. OSHA enforcement policy regarding the use of consensus standards is that a violation ...

    Get Price
  • 1926.307 - Mechanical power-transmission apparatus ...

    2 天前 · Where both runs of horizontal belts are 7 feet (2.128 m) or less from the floor level, the guard shall extend to at least 15 inches (38.1 cm) above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches (106.68 cm) or less from the floor, the belt shall be fully enclosed.

    Get Price
  • OSHA Standards on Machine Guarding

    2017-11-30 · 2017-11-30 · OSHA Standards on Machine Guarding The OSHA standards on general guarding of machinery and mechanical power transmission apparatus (29 CFR 1910.212 and 1910.219) are very broad and generally minimum guarding standards. One standard was predicated on the 1970’s version of the ANSI/ASME B15.1 standard, which itself had

    Get Price
  • How To Use a Guard Opening Scale - Machine Safety

    2013-2-2 · 2013-2-2 · OSHA 1910.212 (a) (2) Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. OSHA 1910.212 (a) (3) (ii) The point of operation of machines should be guarded.

    Get Price
  • Guarding Floor and Wall Openings and Holes — OSHA

    2013-5-22 · Guarding Floor and Wall Openings and Holes — OSHA Standard 1910.23 2 Overview This is a condensation of Standard 1910.23 of the Occupational Safety and Health Act. This document is not intended to be totally inclusive but rather to highlight the information and requirements in the complete OSHA standard that all owners and

    Get Price
  • OSHA Standard 1910.242(b) – Dead-End Pressure and

    2017-7-27 · OSHA Standard 1910.242(b) discusses the use of compressed air for cleaning and blowoff. It states that the use of compressed air for cleaning purposes is prohibited if the dead-ended pressure exceeds 30 psig. This phrase means the downstream pressure of the air nozzle or gun, used for cleaning purposes, will remain at a pressure level…

    Get Price
  • API 671 Coupling Standard | Coupling Answers |

    2014-10-15 · Method 2 is the standard for applications operating above 1,800 rpm. While the major components are balanced as with Method 1, the coupling is fully assembled and the balance of the entire coupling is verified prior to shipment. Method 3 is similar to Method 1 where the major components are individually balanced.

    Get Price
  • Ansi Compliant Coupling Guard, कपलिंग गार्ड in

    OSHA Handrail Standards. Here are some basic pieces of information to bear in mind when constructing a handrail to comply with OSHA Standards. The top rail of the handrail must be a minimum of 42' [ref. 1910.23 (e) (1)] The intermediate (middle) rail should be located in the middle of the upright creating equal space between the floor and the ...

    Get Price
  • OSHA Handrail | How To Project Guide

    2019-3-3 · OSHA, known as the Occupational Safety and Health Administration, is a United States federal agency that regulates and enforces workplace safety and health. The OSH Act covers most private sector employers and their workers and OSHA standards generally only apply in a workplace. The stairway structure must first only be for the use of workers

    Get Price
  • OSHA vs IBC Approved Stairs — What is the difference,

    2007-4-24 · Flexibility is sometimes good as rigid will not have the 'slowing' action. Expanding metal is also good but it must be adequate for the job. Of course; overkill is not so bad when it comes to protecting body parts. Design for a glancing blow and containment is a consideration as the blow can be absorbed and contained within the housing. But when you question automatically, generally it is a ...

    Get Price
  • flimsy coupling guard ok? | AMP Maintenance Forums

    Shaft Coupling Covers. Extend the life of your rigid shaft couplings by blocking out dirt, water, lubricants, and other contaminants. These two-piece covers twist together to form a shell around the coupling.

    Get Price
  • Rexnord ''Orange Peel'' Coupling Guard for Motor

    2020-10-26 · The metatarsal guard also known as Met Guards or Meta Guard is a protective device use to protect the metatarsals. Before we continue, lets understand the part of the body we call the metatarsal. The metatarsal bones are the five (5) long thin bones of the midfoot which connects the toes to the ankle and can break easily.

    Get Price
  • Four OSHA Regulations You Should Know for

    2013-2-2 · OSHA 1910.212 (a) (2) Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. OSHA 1910.212 (a) (3) (ii) The point of operation of machines should be guarded.

    Get Price
  • [email protected] www.idcon.com CONDITION

    2020-6-25 · allowed size of the wire mesh depends on the distance from the coupling to the mesh. For example a 1-inch (25.4 mm) wire mesh must be at least 1.5 inches (38.1 mm) away from the coupling. If your plant applies higher standards than OSHA, make a wire mesh according to OSHA standard, then apply a hinged lid over the wire mesh. Guard modification is

    Get Price
  • Standards for Guardrail and Handrail Systems | W.S.

    OSHA 1910.23(e)(1): “ A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing.

    Get Price
  • Falk 'Orange Peel' Pump Coupling Guards -

    OSHA, ANSI AND ASMI APPROVED. 'Orange Peel' Coupling Guards from Rexnord's Falk Division are OSHA, ANSI and ASME approved and provide the optimum in safety for your plant. When installed properly, all gaps are less than 0.25' to meet the OSHA standards for rotating equipment guards. Falk Orange Peel guards are also economical and easy to install.

    Get Price
  • API 671 Coupling Standard | Coupling Answers |

    2014-10-15 · Method 2 is the standard for applications operating above 1,800 rpm. While the major components are balanced as with Method 1, the coupling is fully assembled and the balance of the entire coupling is verified prior to shipment. Method 3 is similar to Method 1 where the major components are individually balanced.

    Get Price
  • OSHA machine guarding standard | 2019-01-01 | ISHN

    OSHA Handrail Standards. Here are some basic pieces of information to bear in mind when constructing a handrail to comply with OSHA Standards. The top rail of the handrail must be a minimum of 42' [ref. 1910.23 (e) (1)] The intermediate (middle) rail should be located in the middle of the upright creating equal space between the floor and the ...

    Get Price
  • OSHA Handrail | How To Project Guide

    2015-2-10 · OSHA’s directive 1910.242(b) states “Compressed air shall not be used for cleaning purposes except where reduced to less than 30 PSIG and then only with effective chip guarding and personal protective equipment.” This standard is unclear in a vacuum, but in 1978 OSHA released OSHA instruction STD 01-13-0001 (which also includes acceptable methods), which gave an interpretation …

    Get Price
  • Complying with OSHA’s Compressed Air Standard

    Shaft Coupling Covers. Extend the life of your rigid shaft couplings by blocking out dirt, water, lubricants, and other contaminants. These two-piece covers twist together to form a shell around the coupling.

    Get Price
  • Shaft Coupling Guards | McMaster-Carr

    2019-6-25 · OSHA regulations for gas can storage and handling state that 'only approved containers and portable tanks shall be used.' Regulations go on to state that when it comes to the handling and use of flammable liquids in quantities of 5 gallons or less, only 'approved safety cans or Department of Transportation (DOT) approved containers shall be used.'

    Get Price